The increased admissible tensile force of speedpipe ground especially pays off in the tight relation of the existing capacity to the outer diameter of the speedpipe. Nevertheless, to use the residual space, a cutting device removes the lose duct coat before the drawing-in process. A pulling head that is directly placed on the ends of the speedpipe fixes the single ducts and guarantees an optimum focus of power - without taking more space in the duct. Thus also bundles with more than eight internal speedpipe or additional single ducts can be fed into the duct.
Mainly use in practice of the microducts for blowing in fibre optics up to the building: FTTB and FTTH
Each subduct system only is as good as its resistance! For long usability and for the protection of your active network technologies gas-, dirt- and water-tight sealing and fixing elements are essential.
Name | L (m) | speedpipe amount | speedpipe Dxs (mm) | kg / m | G (kg)* | Variant | Art. No. |
---|---|---|---|---|---|---|---|
SRV-G 32 / 6 × 7** | 4000 | 6 | 7×1,5 | ca. 0,20 | ca. 1100 | gabo | 3834 |
SRV-G 40 / 8 × 7 | 4000 | 8 | 7×1,5 | ca. 0,26 | ca. 1300 | gabo | 3838 |
SRV-G 50 / 10 × 7 | 4000 | 10 | 7×1,5 | ca. 0,35 | ca. 1600 | gabo | 3836 |
SRV-G 40 / 14 × 7 | 3500 | 14 | 7×1,5 | ca. 0,40 | ca. 1800 | DIN | 2363 |
SRV-G 50 / 18 × 7 | 1950 | 18 | 7×1,5 | ca. 0,55 | ca. 1400 | DIN | 3830 |
SRV-G 50 / 24 × 7 | 1800 | 24 | 7×1,5 | ca. 0,70 | ca. 1650 | gabo | 1672 |
SRV-G 40 / 14 × 7 | 3500 | 14 | 7×1,5 | ca. 0,40 | ca. 1800 | gabo | 3067 |
SRV-G 50 / 18 × 7 | 1950 | 18 | 7×1,5 | ca. 0,55 | ca. 1400 | gabo | 3828 |
* Total weight including spool
** after technical clarification
Delivery of these SRV-G on a wooden one-way spool: 2400 × 1200mm
Name | Colour | L (m) | Dxs (mm) | Pressure level | kg / m | G (kg)* | Art. No. |
---|---|---|---|---|---|---|---|
speedpipe ground 12 × 2,0 | yellow-green | 2000 | 12 x 2,0 | PN 16 | ca. 0,06 | ca. 150 | 2175 |
speedpipe ground 14 × 2,0 | orange | 1500 | 14 x 2,0 | PN 16 | ca. 0,074 | ca. 140 | 4134 |
speedpipe ground 16 × 2,0 | turquoise | 1200 | 16 x 2,0 | PN 10 | ca. 0,084 | ca. 130 | 42302 |
* Total weight including spool
Delivery of these speepipe on a wooden one-way spool: 1200 × 370mm
Download description | Category | Last update | |
---|---|---|---|
SRV-G 40 / 14 × 7Access to the document, register here. | 29.09.2021 | ||
Laying Instructions SRV-G / SRV-G tc | Installation instructions | 11.01.2022 | |
speedpipe ground 12 × 2,0Access to the document, register here. | Technical data sheets | 22.06.2022 | |
speedpipe ground 14 × 2,0Access to the document, register here. | Technical data sheets | 22.06.2022 | |
speedpipe ground 16 × 2,0Access to the document, register here. | Technical data sheets | 22.06.2022 | |
SRV-G 32 / 6 × 7Access to the document, register here. | Technical data sheets | 29.09.2021 | |
SRV-G 40 / 8 × 7Access to the document, register here. | Technical data sheets | 29.09.2021 | |
SRV-G 50 / 10 × 7Access to the document, register here. | Technical data sheets | 29.09.2021 | |
SRV-G 50 / 18 × 7Access to the document, register here. | Technical data sheets | 29.09.2021 | |
SRV-G 50 / 24 × 7Access to the document, register here. | Technical data sheets | 29.09.2021 | |
Installation concepts in fibre optic expansionAccess to the document, register here. | Whitepaper | 23.12.2021 |