speed•pipe® bundle ground gabo Systemtechnik SRV-G und SRV-G tc Laying instructions 25 Micro cable / mini cable • The cable diameter should be within the specified diameter ranges (see table). speed•pipe® min. cable diameter* max. cable diameter* 7 × 1.5 1 mm 2.7 mm 10 × 2.0 1.8 mm 4.6 mm 12 × 2.0 3 mm 6.8 mm 14 × 2.0 3 mm 8.7 mm 16 × 2.0 6.5 mm 10.4 mm 20 × 2.5 8 mm 12.5 mm * Including tolerances • The cable diameter has a significant influence on the blowing in length. • The cable diameter should be uniform and should not vary for more than 0.3 mm. • The cable sheath should be as smooth as possible • The surface of the micro cable should be dry and clean and should not exceed temperatures of more than 25 °C (ideal 15 °C). • The cable ideally has been optimised to the gabocom speed•pipe® and has been certified on a test track. • The cable shouldn’t have any axial run out.