gabocom | speedpipe® bundle ground SRV-G and SRV-G tc. Laying instructions.

gabo Systemtechnik speed•pipe® bundle ground Laying instructions SRV-G und SRV-G tc 12 The following branch off procedure is valid for speed•pipe® bundles which were laid or plowed in open trenches. If the speed•pipe® bundles were pulled in ducts it is recommended to work with HRMA. The branching off from the SRV-G should always realise with the help of branch off equipment (TBS / LBS), so it is guaranteed that the minimum bending radius is compliant and also a kinking during the compression process is prevented. The coat duct of the speed•pipe® bundle should be opened with a suitable cutting tool (sheat cutter with sliding guide, see point 4) to a length of 80 – 100 cm. The branching off speed•pipe® should be cutted with a speed•pipe® cutter (see point 5) in front of the branch off equipment and connect it with DSM to the single duct or the branch off speed•pipe® bundle. Fix the speed•pipe® in the branch off equipment with an cable ties in the prepared holes so the speed•pipe® are laying in the predefined bending radius. Optionally a ball marker can be mounted for location on the branch off equipment with cable ties. Option Note: Avoid connectors in a bending radius as they can stop the blowing in process because of the internal edge of the open middle plot. 7. Branching off the speed•pipe® bundle ground.