gabo Systemtechnik Laying instructions. 17 speed•pipe® bundle SRV 50 / 8 x 10 Laying instructions. 6.6 Deflecting of drawn through SRV in the cable duct. Laying instructions. 6.7 Connecting the SRV in the cable duct. Please note: After having fixed the SRV in the KKR 110, the bundle must be deflected in the manhole in a way that it doesn’t obstruct further infeed and extracting works and that there is no risk of damage during these works. Additionally, the speed•pipe® bundle must not be placed in the direct access area of the manhole. With regard to the blowing in lengths choose quite wide bending radii! LAYING INSTRUCTIONS: 1) Cut both jacket pipes (together at least 1 m). 2) Seal both ends of the bundle with EZA-t 50 / 8 x 10. 3) Afterwards cut the single speed•pipe® each shifted for at least 120 mm. A straight, right-angled cut to the pipe axis is observed! 4) Connect the speed•pipe® of the same colour with DSM 10.
RkJQdWJsaXNoZXIy MTYzMjU=