gabocom | speedpipe® bundle SRV 50 / 8 x 10

gabo Systemtechnik Laying instructions. 15 speed•pipe® bundle SRV 50 / 8 x 10 Laying instructions. 6.4 Sealing and fixing the SRV to the cable duct conduit. Sealing and fixing the speed•pipe® bundle SRV 50 / 8 x 10 to the KKR 110 in the cable duct is carried out by using the sealing element ADE / TDUX 100 (tyco / CommScope) and is necessary on both sides in each manhole. For stiffening the jacket pipe, first attach an outside stiffener (SHa) or in case of double occupation with SRV an outside double stiffener (DSHa) around the bundle, see „Assembly instruction for outside stiffener“. 2) Combined installation of the outside stiffener SHa and tyco / CommScope ADE / TDUX into the KKR 110. 3) Filling and sealing the tyco / CommScope ADE / TDUX. 1) The outside stiffener SHa is put onto the jacket pipe of the SRV. APPLICATION STEPS: