gabo Systemtechnik Laying instructions 21 speed•pipe® indoor Network level 4 The test track „Outdoor“ for the tests measures 1250 m length and includes four 90 ° arches with R = 2.5 m, as well as eight 180 ° arches with R = 7.5 m. speed•pipe® indoor 10 x 1.0 speed•pipe® indoor 12 x 2.0 Outer diameter fibre optic cable Ø 6.3 mm TEST TERRAIN GABOCOM The installation of speed•pipe® indoor in buildings generally is subject to different rules and parameters than in the outdoor area. The adaptation to the local laying paths requires frequent bends of speed•pipe® indoor. These pipe bends require particular attention with regard to the bending radius, which should not fall below a radius of 10 × of the pipe diameter in the case of free bending (no bending control element). This ensures that the ovality of the speed•pipe® indoor in the bending area reduces the free internal diameter only within the limits specified. Rules for the assignment of speed•pipe® indoor in buildings: 1250 m total length R 2.5 m R 7.5 m